1.With 3 functions, 5 modes:
* Single hot water *Single heating * Single cooling
* Hot water + Cooling * Hot water + Heating
2.DC Inverter compressor and R410A refrigerant.
3.Million units already installed, good quality approved.
PRODUCTS
With R410a refrigerant, does not destroy the ozone layer, ODP ) is 0. Its molecular formula does not contain chlorine. Very low toxicity. Nonflammable. The flammable polarity in air is 0.
Water output temperature can reach 58℃ even when ambient temperature is -25℃.
With 3 functions, 5 modes:
* Single hot water *Single heating * Single cooling
* Hot water + Cooling * Hot water + Heating
Coaxial heat exchanger, larger pipe diameter, not easy to be blocked due to scaling, easier to clean and reduce water resistance.
With high quality expansion tank inside, save installation costs and time.
Built-in adjustable electric back-up of 3KW, faster heating for your room when there is requirement, also more stable heating when weather is extremely cold.
Built-in high quality circulation pump, save your time for installation.
DC INVERTER SPLIT TYPE HEAT PUMP FOR COOLING & HEATING & HOT WATER
Model | RF8I/bdm | RF12I/bdm | RF13I/bdm | HF20I/bdm | ||
Rated Heating | Heating capacity | KW | 9.00 | 15.00 | 18.00 | 20.00 |
Power input | KW | 2.59 | 4.31 | 5.14 | 5.81 | |
COP | W/W | 3.47 | 3.48 | 3.50 | 3.44 | |
Nominal Heating | Heating capacity | KW | 5.53 | 10.50 | 12.10 | 14.50 |
Power input | KW | 2.34 | 4.43 | 5.13 | 6.01 | |
COP | W/W | 2.36 | 2.37 | 2.36 | 2.41 | |
IPLV(H) | W/W | 2.80 | 2.85 | 2.85 | 2.86 | |
Low Temp. Heating | Heating capacity | KW | 4.50 | 8.90 | 10.10 | 12.50 |
Power input | KW | 2.34 | 4.56 | 5.10 | 5.95 | |
COP | W/W | 1.92 | 1.95 | 1.98 | 2.10 | |
Rated Cooling | Cooling capacity | KW | 8.00 | 11.50 | 12.00 | / |
Power input | KW | 3.20 | 4.60 | 4.80 | / | |
EER | W/W | 2.50 | 2.50 | 2.50 | / | |
Power Supply | V/Ph/Hz | 220/1/50 | ||||
Max. Power Input (With E-Heater) | KW | 4.4(+3) | 5.2(+3) | 6.6(+3) | 7.1(+3) | |
Max. Current Input (With E-Heater) | A | 20(+13.6) | 23.7(+13.6) | 30(+13.6) | 32.5(+13.6A) | |
Max. Water Temp.(Without E-Heater) | ℃ | 58 | ||||
Working Range (Ambient temp.) | ℃ | -30 to 43 | -35 to 43 | |||
Refrigeration Circulation | Refrigerant | Type | R410A | |||
Qty./Kg | 1.7 | 3.15 | 3.15 | 3.15 | ||
Compressor | Qty. | 1 | ||||
Type | DC INVERTER DOUBLE ROTOR | EVI DC INVERTER DOUBLE ROTOR | ||||
Brand | GMCC | |||||
Evaporator | Type | High efficiency hydrophilic aluminum foil fin heat exchanger | ||||
EEV | Brand | SANHUA | ||||
Fan Motor | Qty. | 1 | 2 | |||
Power Input(W) | 140 | 2*150 | ||||
Fan Blades Size | mm | Φ560*139 | Φ525*135 | |||
Liquid valve size | inch(mm) | 3/8"(9.52) | ||||
Gas valve size | inch(mm) | 5/8"(15.88) | ||||
Water system | Condenser | Type | Tube in tube heat exchanger | |||
Water Pump | Brand | XINHU | ||||
Model | GPD25-12S | |||||
Water Flow | m³/h | 1.38 | 1.98 | 2.06 | 2.5 | |
Water Drop | kpa | 35 | 35 | 38 | 48 | |
Air Vent Valve | / | Standard | ||||
Pressure Release Valve | / | Standard | ||||
Pressure value | 3kgs | |||||
E-Heater | KW | 3 | ||||
Buffer Tank | L | 5 | ||||
Water Inlet/Outlet Pipe | inch(mm) | 5/4" male | ||||
Net Dimensions | indoor Unit(L*W*H) | mm | 760x510x330 | |||
Outdoor Unit(L*W*H) | mm | 947x403x813 | 940x393x1373 | |||
Package Size | indoor Unit(L*W*H) | mm | 795x562x373 | |||
Outdoor Unit(L*W*H) | mm | 1050x468x847 | 1060x490x1395 | |||
N.W. | Indoor Unit | kg | 43 | |||
Outdoor Unit | kg | 63 | 110 | 115 | ||
G.W. | Indoor Unit | kg | 48 | |||
Outdoor Unit | kg | 70 | 125 | 130 | ||
Noise Level | Indoor Unit | dB(A) | ≤35 | |||
Outdoor Unit | dB(A) | ≤59.5 | ≤61.5 | ≤62 |
Product Photo
"Product implementation standards: GB/T 25127.2-2010 GB/T 18430.2-2016 Testing Condition:
- Rated heating: Inlet/outlet temperature 40°C/45°C. Dry bulb/wet bulb temperature 7°C/6°C
- Nominal heating: Outlet temperature 41°C. Dry bulb/wet bulb temperature -12°C/-14°C
- Low temperature heating: Outlet temperature 41°C. Dry bulb/wet bulb temperature -20°C/-21°C
- Rated cooling: Inlet/outlet temperature 12°C/7°C. Dry bulb/wet bulb temperature 35°C/24°C
- Internal and external machine connection copper pipe are 5m. If need for exceeds 7.5m, you need to contact the manufacturer to change the amount of refrigerant."
CONTCT US
If you have any questions about our products, you are welcome to call us at any time
zhejiang CEN New Energy Stock Co,.Ltd
Add:No:468 Haning Road,Yucheng Town,Haiyan,Zhejiang Province,China.
Email: aegean_heatpump@cn-xny.com.cn
TEL:+86-573-86226973